Use a regulated, isolated 5 V supply or a suitable battery source. The probe header connects only to this low-voltage circuit, never to mains-powered tank hardware. R1 limits current from +5V into probe A. Probe B reaches Q1’s base, with a 1 MΩ pulldown. The probes are not modelled as a switch that works identically in every liquid: clean water can conduct too weakly, while deposits and moisture can create leakage paths.
Dry logic: Q1 is off, its 4.7 kΩ collector pullup drives Q2 through 100 Ω, and Q2 holds the 555 RESET low. Wet logic: enough probe current turns Q1 on, pulling its collector low and turning Q2 off. The 1 kΩ RESET pullup then enables the timer. This extra inversion makes a wet condition enable sound rather than disable it.
With a 10 kΩ test resistor bridging the probes, assumed VBE = 0.7 V and VCE(sat) = 0.2 V, the resistor/switch libraries compute 0.134 mA net Q1 base drive and 1.021 mA collector load. The forced-beta-10 target is 0.102 mA. R1 is 22 kΩ; even a zero-resistance probe bridge has a supply-current bound of 0.227 mA through that resistor. These are nominal assumptions, not a guaranteed liquid-detection resistance threshold.
The dry-state Q2 drive is nominally 0.889 mA, after its base pulldown. Its RESET sink budget is 6.300 mA, including the resistor current and the NE555 datasheet’s low-reset current allowance; the forced-beta-10 base target is 0.630 mA. A direct high-resistance probe connection to a bipolar timer’s RESET is deliberately avoided. Verify the actual NE555 electrical characteristics when substituting a timer family.
The astable uses RA = 1 kΩ, RB = 47 kΩ and C = 10 nF. Running the calculator’s exact timing equations gives 1518.6 Hz, approximately an audible tone, and 50.53% high duty. The passive piezo needs this changing signal; a steady GPIO-style on state would not provide a continuous tone. The output also drives a red LED through its own 1 kΩ resistor. Its ideal 5 V-high, 2 V-forward-drop estimate is 3 mA while high; real output swing makes this an approximation.
Q3 switches the piezo’s lower terminal. A 220 Ω feed resistor limits the initial current estimate to 21.82 mA with the stated supply and saturation assumption, while 10 kΩ across the piezo provides discharge. With an assumed 2.5 V timer high, the 680 Ω base resistor supplies 2.647 mA before the small pulldown current, compared with the nominal 2.182 mA target. Acoustic output still depends on the transducer, mounting and waveform.
DC probes can corrode or contaminate liquid. This is a brief low-voltage demonstration, not a drinking-water installation or a dependable overflow/safety controller. It has no hysteresis and can chatter near a weak-conductivity boundary. Use isolated pads and insulated jumpers, with no stripboard cuts.