The regulated supply is 5 V. R1 is 100 kΩ and C1 is 10 µF. The 555 calculator uses t = 1.1 R C in monostable mode; running that exact formula gives 1.1 seconds for these parts. This is a nominal interval, affected by capacitor tolerance, leakage and the actual timer, not a precision stopwatch.
THRESHOLD and DISCHARGE share the timing node. R1 charges C1 from the supply while the output is high; C1’s negative leg returns to ground. A short low pulse on TRIGGER starts the interval. The 10 kΩ trigger pullup keeps the input high when the normally open external button is released. Do not join trigger to the timing node as in the astable circuit.
Press and release the button promptly, before the intended pulse ends. Holding trigger low can keep the output active beyond the nominal interval. This circuit is not debounced and does not guarantee a defined power-up pulse state. RESET is tied high; use a deliberately designed reset/power-on network if your application requires one. Follow the NE555 datasheet’s monostable connection and trigger guidance.
The output drives the LED through 1 kΩ. With an ideal 5 V output and an assumed 2 V red LED drop, the resistor library computes 3 mA. A bipolar NE555 does not reach the positive rail under load, so the real LED current will be lower and depends on the device. The current calculation is a stated ideal-output estimate, not a measured brightness claim.
C2 bypasses the control pin to ground and C3 bypasses the supply near the IC. Build on isolated pads with insulated jumpers; no stripboard cuts are needed. Continuous copper strips at these coordinates would require a different connection plan. Check unpowered continuity and electrolytic polarity before applying power.