Electrical Power Calculator

Electronics

Calculate watts from volts and amps, amps from watts, and monthly kWh and electricity cost in US dollars, with resistor rating and copper wire loss checks.

Electrical power

60 W

12 V × 5 A

Volts × amps applies to DC or resistive AC at unity power factor. For other AC loads, enter measured real watts in Monthly kWh and cost. No three-phase or power-factor solver.

Monthly energy and cost

14.4 kWh · $2.45/month

Constant real input watts while running; excludes fixed charges, taxes and rate tiers. For cycling loads, use measured average watts or equivalent full-power hours.

Component checks

Optional copper wire loss check

Two equal conductors at nominal 20 °C, using the calculated current. This is a fixed-current loss estimate, not a cable, breaker or safe ampacity recommendation.

Loop resistance: 0.1276902 Ω · Voltage drop: 0.6384512 V · Wire heating: 3.192256 W

If loss or voltage drop is too high, compare a lower AWG number or a shorter run. Check the actual cable’s current rating, insulation, installation and connector limits separately. Large drops also change a real load’s current.

Compare AWG geometry · Solve Ohm’s law · Size an LED resistor

On this browser only

Give feedback

Did this tool help?

Tell us what worked, what didn’t, or what you’d like next.

Opens Google Forms in a new tab with this tool’s name filled in. No sign-in or email required. Feedback is optional.

How to use Electrical Power Calculator

  1. 1Choose watts, amps, or monthly kWh and cost. The loaded example starts with a DC load.
  2. 2Enter volts and amps for watts, or watts and volts for amps. Use real measured watts for non-resistive AC energy estimates.
  3. 3Enter daily operating hours, days in the month and your electricity price in US cents per kWh.
  4. 4Read the answer above the controls and the monthly estimate. Change the editable 17-cent example price to match your bill.
  5. 5For an actual resistor, enable the resistor check. Optionally compare copper wire losses; neither check certifies a safe installation.

About Electrical Power Calculator

Electrical power and monthly running cost

Use this electrical power calculator to move from a device’s voltage and current to watts, or from known watts and voltage to amps. Then estimate the energy used over a month and its cost in US dollars. The loaded example is a constant DC load. Results appear before the controls and update when you change an input. Everything runs in your browser, without uploading a utility bill or circuit description.

The existing Ohm’s law calculator is better when resistance is your starting point. This page adds a direct watts input, monthly kilowatt-hours and cost, plus optional component checks. It does not solve an entire circuit or determine whether a household outlet, breaker or cable is suitable for a device.

Choose the right power relationship

For DC, electrical power is P = V × I. Voltage is measured across the load, and current flows through that same load. To find current from known power, rearrange the formula to I = P / V. Enter volts, amps and watts directly. A milliamp reading must be converted to amps before entering it. Voltage must be positive; zero power or current is accepted.

For AC, multiplying RMS volts by RMS amps gives apparent power. It equals real watts for a resistive load at unity power factor. Motors and electronic power supplies can behave differently. This tool does not include a power-factor input or a three-phase model. For their electricity cost, choose Monthly kWh and cost and enter measured real input watts instead. Do not treat a power supply’s maximum output label as a measurement of its wall consumption.

Worked example: a DC load

The loaded inputs are 12 V and 5 A. Running the calculator’s library gives 60 W. At 8 hours per day, the daily energy is 0.48 kWh. Across the selected 30-day month, the load uses 14.4 kWh. With the editable example price of 17 cents per kWh, the unrounded cost is $2.448, displayed as $2.45 per month.

These figures describe energy at the entered load. If that load is powered through an AC adapter, its wall consumption also includes adapter losses. Enter measured wall watts in energy mode when estimating the electricity bill. Conversely, if you are studying the DC branch itself, keep its voltage and current together and label that boundary in your notes.

A separate resistive-heater example uses 1,500 W and 120 V. Amps mode returns 12.5 A. If it draws that real power for 2 hours each day over 30 days, the energy calculation returns 90 kWh and $15.30 at the same example price. This is arithmetic for a stated operating schedule, not permission to connect a particular heater or a circuit-loading assessment.

Understand kWh and the rate field

A watt measures power; a kilowatt-hour measures energy accumulated over time. The calculator uses daily kWh = watts × hours per day / 1,000, then multiplies by days for the monthly total. Monthly dollars = monthly kWh × cents per kWh / 100. The US Energy Information Administration’s explanation of electricity measurements describes this power-versus-energy distinction.

The 17-cent starting value is an illustrative US price, not a claim about the current national average or your utility. Replace it with the applicable variable rate from your bill. Fixed service charges, taxes, demand charges, tiers and time-of-use periods are outside this single-rate model. Choose the actual number of days for the period you want to compare.

Refrigerators, thermostatic heaters and computers rarely draw one unchanging power all day. Use measured average watts over the relevant schedule, or equivalent full-power operating hours. Avoid using both a reduced average and reduced hours for the same cycling adjustment. A plug-in energy meter can provide a more useful real-consumption input than a maximum nameplate rating.

Resistor rating and wire checks

Enable the resistor option only when the calculated load power is dissipated in one resistor. The tool reuses the LED library’s illustrative 50% power margin and rounds the minimum upward to a hundredth of a watt. For 0.24 W, the minimum is 0.36 W and the smallest listed common rating is 1/2 W. This is a starting part comparison: the datasheet’s temperature derating, working voltage, cooling and mounting requirements still apply. For an LED branch, use the dedicated LED resistor calculator.

The optional wire check reuses the AWG copper geometry library. It models a pair of equal conductors at nominal 20 °C using your one-way length in feet. With AWG 18, 10 ft one way and 5 A, the loop resistance is about 0.1276902 Ω, voltage drop 0.6384512 V and heating 3.192256 W. These are fixed-current estimates. Compare a shorter run or a lower AWG number if losses are too high, then check the actual cable and installation ratings separately. The library has no ampacity model, so this page deliberately provides no safe-current or breaker-size recommendation.

Guides and tutorials

Frequently asked questions

How do I calculate watts from volts and amps?

For DC or resistive AC at unity power factor, multiply volts by amps: P = V × I. The loaded 12 V, 5 A example gives 60 W.

How do I convert watts to amps?

Divide watts by a positive voltage: I = P / V. For example, 1,500 W at 120 V gives 12.5 A under the stated DC or unity-power-factor assumption.

How do I calculate monthly kWh?

Multiply watts by daily operating hours and days in the month, then divide by 1,000. Use real input watts and a schedule that reflects cycling or variable operation.

Is 17 cents per kWh my electricity rate?

No. It is an editable example price in US cents, not a current national average. Enter your applicable utility rate; fixed charges, taxes and tiered or time-dependent rates are not modeled.

Can I use this for motors or three-phase AC?

The volts-and-amps modes do not model power factor or three-phase systems. Use measured real watts in monthly cost mode for an energy estimate; use an appropriate AC model for current calculations.

Does this duplicate the Ohm’s law calculator?

The power relationship overlaps, but this page accepts watts directly to calculate current and adds monthly kWh, US-dollar cost and optional component checks. Use Ohm’s law when resistance is a known or missing value.

Does the resistor suggestion guarantee a safe part?

No. It applies the existing library’s illustrative 50% margin and chooses from its common-rating list through 5 W. Check the manufacturer’s derating, voltage, mounting and cooling requirements.

Can this tell me which wire gauge or breaker to buy?

No. It estimates nominal copper loop resistance, voltage drop and heating at a fixed current. Safe ampacity depends on cable construction and installation conditions that are not inputs here.

Why does clearing a field remove my result?

Blank, negative, invalid or unrepresentable inputs do not describe a supported calculation. The affected answer clears to avoid showing stale values. Zero watts, hours or price are valid; voltage must stay positive.

Are adapter losses and standby power included?

Only if they are included in your entered real input watts and operating schedule. A DC load calculation alone does not include upstream adapter losses, and the tool does not add an automatic standby allowance.