Every 32-bit RISC-V base integer instruction (RV32I) belongs to one of six core formats: R-type, I-type, S-type, B-type, U-type, or J-type. Understanding how these formats slice up a 32-bit instruction word is essential for assembling assembly code into machine hex, decoding raw binary dumps, or building pipelined datapath control units in computer architecture courses (such as UC Berkeley CS 61C or MIT 6.1910).

This guide walks through each of the six RV32I formats with bit-level field definitions, design rationales, and concrete worked examples computed directly with the site's instruction encoder library.

RV32I Architecture Principles

The RISC-V instruction set architecture (ISA) was designed with three hardware priorities:

  1. Fixed instruction length: Every RV32I instruction is exactly 32 bits wide, aligned on a 4-byte memory boundary (bits [1:0] are always 11 for standard base instructions).
  2. Fixed register specifier positions: The source registers rs1 (bits [19:15]) and rs2 (bits [24:20]), as well as the destination register rd (bits [11:7]), always appear in the identical bit slots whenever present. This allows register file reads to proceed in parallel with opcode decoding, eliminating decode-stage multiplexers and shortening critical clock paths.
  3. Fixed sign-bit position: In every format that contains an immediate field (I, S, B, U, and J), the most significant bit of the immediate is wired directly to bit [31] of the instruction. The hardware sign-extension tree always draws from bit [31] without multiplexing.

Format Overview

The table below summarizes the six formats and their bit allocations:

Format Bits [31:25] (7) Bits [24:20] (5) Bits [19:15] (5) Bits [14:12] (3) Bits [11:7] (5) Bits [6:0] (7) Purpose
R funct7 rs2 rs1 funct3 rd opcode Register-register ALU ops
I imm[11:0] rs1 funct3 rd opcode Immediate ALU, loads, jalr
S imm[11:5] rs2 rs1 funct3 imm[4:0] opcode Memory stores (sw, sh, sb)
B imm[12|10:5] rs2 rs1 funct3 imm[4:1|11] opcode Conditional branches
U imm[31:12] rd opcode Upper immediate (lui, auipc)
J imm[20|10:1|11|19:12] rd opcode Unconditional jump (jal)

1. R-Type (Register-Register)

R-type instructions operate purely on processor registers: two source registers (rs1 and rs2) supply input operands to the ALU, and the calculated result is written back to destination register rd.

Bit Layout

[31:25] funct7 (7 bits)
[24:20] rs2    (5 bits)
[19:15] rs1    (5 bits)
[14:12] funct3 (3 bits)
[11:7]  rd     (5 bits)
[6:0]   opcode (7 bits) = 0110011 (0x33)
  • opcode (bits [6:0]): Standard value 0110011 (0x33) identifies RV32I integer register-register operations.
  • rd (bits [11:7]): 5-bit destination register index (x0 through x31).
  • funct3 (bits [14:12]): 3-bit sub-operation selector (e.g., 000 for add/sub, 111 for and, 010 for slt).
  • rs1 (bits [19:15]): 5-bit first source register index.
  • rs2 (bits [24:20]): 5-bit second source register index.
  • funct7 (bits [31:25]): 7-bit function modifier (0000000 for add, 0100000 for sub or arithmetic shift).

Worked Example: add x1, x2, x3

Add the contents of x2 (stack pointer sp) and x3 (global pointer gp), storing the sum into x1 (return address ra):

Field Bits Binary Value Description
funct7 [31:25] 0000000 0x00 Standard addition operation variant
rs2 [24:20] 00011 3 (gp) Second source register x3
rs1 [19:15] 00010 2 (sp) First source register x2
funct3 [14:12] 000 0x0 Addition ALU selector
rd [11:7] 00001 1 (ra) Destination register x1
opcode [6:0] 0110011 0x33 R-type integer ALU opcode

Combining the fields:

Binary:  0000000 00011 00010 000 00001 0110011
Grouped: 0000 0000 0011 0001 0000 0000 1011 0011
Hex:     0x003100B3

Notice how sub x1, x2, x3 would differ in only a single bit: funct7 would become 0100000 (bit 30 = 1), yielding hex 0x403100B3.


2. I-Type (Immediate & Loads)

I-type instructions encode an operation between one register operand (rs1) and a 12-bit signed immediate constant. They are used for immediate arithmetic (addi, andi, slti), memory loads (lw, lh, lb), and indirect jumps (jalr).

Bit Layout

[31:20] imm[11:0] (12 bits)
[19:15] rs1       (5 bits)
[14:12] funct3    (3 bits)
[11:7]  rd        (5 bits)
[6:0]   opcode    (7 bits)

The 12-bit immediate field imm[11:0] is sign-extended in hardware to 32 bits, allowing values in the range [-2048, +2047].

Worked Example: addi x5, x4, 5

Add the immediate constant +5 to register x4 (tp), writing the result into x5 (t0):

Field Bits Binary Value Description
imm[11:0] [31:20] 000000000101 5 12-bit signed immediate constant
rs1 [19:15] 00100 4 (tp) Source register x4
funct3 [14:12] 000 0x0 addi operation variant
rd [11:7] 00101 5 (t0) Destination register x5
opcode [6:0] 0010011 0x13 I-type integer ALU opcode

Combining the fields:

Binary:  000000000101 00100 000 00101 0010011
Grouped: 0000 0000 0101 0010 0000 0010 1001 0011
Hex:     0x00520293

Negative Immediates and Sign Extension

When an immediate is negative, its two's complement sign bit is 1. For example, addi sp, sp, -16 (stack frame allocation):

  • -16 in 12-bit two's complement is 1111 1111 0000 (0xFF0).
  • rs1 = 00010 (sp), rd = 00010 (sp), funct3 = 000, opcode = 0010011.
  • Assembled binary: 111111110000 00010 000 00010 0010011 -> 0xFF010113.

Shift Instructions: Specialized I-Type

For immediate shifts (slli, srli, srai), the shift amount only requires 5 bits (0 to 31). The 12-bit immediate is therefore divided:

  • Bits [24:20] contain the 5-bit shift amount (shamt).
  • Bits [31:25] function as an auxiliary funct7 field (0000000 for logical shifts, 0100000 for arithmetic right shift srai).

3. S-Type (Store)

S-type instructions store data from register rs2 into a memory location computed as rs1 + offset. Because store instructions do not write to a destination register, there is no rd field.

Why Is the Immediate Split?

Instead of placing all 12 immediate bits in bits [31:20] (which would force rs2 to move), RISC-V splits the immediate:

  • Upper 7 bits: imm[11:5] occupy bits [31:25].
  • Lower 5 bits: imm[4:0] occupy bits [11:7] (where rd is located in R-type and I-type).

This clever choice ensures that rs1 ([19:15]) and rs2 ([24:20]) remain in the exact same physical bit positions as in R-type instructions. The hardware register read ports connect directly to those bit lanes without needing an extra input multiplexer.

Bit Layout

[31:25] imm[11:5] (7 bits)
[24:20] rs2       (5 bits) - Source data to store
[19:15] rs1       (5 bits) - Base address register
[14:12] funct3    (3 bits) - Store width: 000=sb, 001=sh, 010=sw
[11:7]  imm[4:0]  (5 bits)
[6:0]   opcode    (7 bits) = 0100011 (0x23)

Worked Example: sw x1, 12(x2)

Store the 32-bit word in register x1 (ra) to the memory address at x2 + 12 (sp + 12):

  • Immediate value: 12 = 0000 0000 1100 in 12-bit binary.
  • imm[11:5] = 0000000 (upper 7 bits).
  • imm[4:0] = 01100 (lower 5 bits, decimal 12).
  • rs2 = 00001 (x1, the register holding the word to be written).
  • rs1 = 00010 (x2, base stack pointer).
  • funct3 = 010 (32-bit word store).
  • opcode = 0100011 (0x23).
Field Bits Binary Value Description
imm[11:5] [31:25] 0000000 0 Upper 7 bits of store offset
rs2 [24:20] 00001 1 (ra) Data register to store
rs1 [19:15] 00010 2 (sp) Base address register
funct3 [14:12] 010 0x2 Store word (sw) width
imm[4:0] [11:7] 01100 12 Lower 5 bits of store offset
opcode [6:0] 0100011 0x23 S-type store opcode

Combining the fields:

Binary:  0000000 00001 00010 010 01100 0100011
Grouped: 0000 0000 0001 0001 0010 0110 0010 0011
Hex:     0x00112623

4. B-Type (Conditional Branch)

B-type instructions compare two registers (rs1 and rs2) and, if the condition is met, perform a program-counter-relative jump (PC = PC + offset).

Bit Layout and Scrambling

Instructions in RV32I must be aligned to even byte addresses (2-byte multiples for compressed C extension, 4-byte for base RV32I). Therefore, the lowest bit of any branch target offset (imm[0]) is always 0 and is not stored in the instruction word. This gives a 13-bit signed offset imm[12:0] with a jump reach of +/- 4 KB.

To maximize hardware reuse with the S-type layout, the bits of the immediate are positioned as follows:

[31]    imm[12]   (1 bit)  - Sign bit remains at bit 31
[30:25] imm[10:5] (6 bits) - Aligned with S-type imm[10:5]
[24:20] rs2       (5 bits) - Comparison source register 2
[19:15] rs1       (5 bits) - Comparison source register 1
[14:12] funct3    (3 bits) - Branch condition (beq, bne, blt, bge, bltu, bgeu)
[11:8]  imm[4:1]  (4 bits) - Aligned with S-type imm[4:1]
[7]     imm[11]   (1 bit)  - Sits in bit 7
[6:0]   opcode    (7 bits) = 1100011 (0x63)

Notice the alignment beauty: bits [30:25] map imm[10:5], and bits [11:8] map imm[4:1], perfectly matching S-type bit positions. Only imm[11] sits in a dedicated slot (bit 7) while the sign bit stays firmly at bit [31].

Worked Example: beq x1, x2, 16

Branch to PC + 16 if register x1 (ra) equals x2 (sp):

  • Branch offset: +16 bytes = 0b0000000010000 (13-bit binary).
  • imm[12] = 0
  • imm[11] = 0
  • imm[10:5] = 000000
  • imm[4:1] = 1000 (since offset is 16 = 2⁴, bits [4:1] are 1000)
  • imm[0] = 0 (omitted from machine code)

Assemble the fields into instruction word slots:

  • Bits [31:25] (imm[12|10:5]): 0 + 000000 = 0000000
  • Bits [24:20] (rs2): 00010 (x2)
  • Bits [19:15] (rs1): 00001 (x1)
  • Bits [14:12] (funct3): 000 (beq)
  • Bits [11:7] (imm[4:1|11]): 1000 + 0 = 10000
  • Bits [6:0] (opcode): 1100011 (0x63)
Field Bits Binary Value Description
imm[12|10:5] [31:25] 0000000 0 Sign bit (0) and offset bits 10:5
rs2 [24:20] 00010 2 (sp) Source comparison register 2
rs1 [19:15] 00001 1 (ra) Source comparison register 1
funct3 [14:12] 000 0x0 beq equality condition
imm[4:1|11] [11:7] 10000 16 Offset bits 4:1 (1000) and bit 11 (0)
opcode [6:0] 1100011 0x63 B-type conditional branch opcode

Combining the fields:

Binary:  0000000 00010 00001 000 10000 1100011
Grouped: 0000 0000 0010 0000 1000 1000 0110 0011
Hex:     0x00208863

5. U-Type (Upper Immediate)

U-type instructions provide a way to load large 20-bit constants into the upper 20 bits of a register (rd), setting the lower 12 bits to zero. They are used by lui (Load Upper Immediate) and auipc (Add Upper Immediate to PC).

Bit Layout

[31:12] imm[31:12] (20 bits)
[11:7]  rd         (5 bits)
[6:0]   opcode     (7 bits) - 0110111 (0x37) for lui, 0010111 (0x17) for auipc

Worked Example: lui x5, 0x12345

Load the 20-bit hex value 0x12345 into register x5 (t0), producing value 0x12345000:

Field Bits Binary Value Description
imm[31:12] [31:12] 00010010001101000101 0x12345 20-bit upper immediate
rd [11:7] 00101 5 (t0) Destination register x5
opcode [6:0] 0110111 0x37 U-type LUI opcode

Combining the fields:

Binary:  00010010001101000101 00101 0110111
Grouped: 0001 0010 0011 0100 0101 0010 1011 0111
Hex:     0x123452B7

Constructing 32-Bit Constants (LUI + ADDI)

Because RV32I instructions are only 32 bits wide, loading an arbitrary 32-bit constant requires two instructions:

  1. lui rd, upper20 loads the upper 20 bits.
  2. addi rd, rd, lower12 adds the lower 12 bits.

Important catch: The addi instruction sign-extends its 12-bit immediate. If bit 11 of the constant is 1 (meaning the lower 12 bits are negative when interpreted as signed), addi will subtract from the upper bits. To compensate, the assembler adds 1 to the upper 20 bits in the lui instruction whenever bit 11 of the constant is set.


6. J-Type (Unconditional Jump)

J-type is used solely for the jal (Jump and Link) instruction. It stores the return address PC + 4 into rd and jumps to PC + offset.

Bit Layout and Scrambling

Like B-type branches, jump targets must be 2-byte aligned, so bit 0 is implicitly 0 and omitted. The instruction encodes a 21-bit signed offset imm[20:0], allowing jumps of +/- 1 MB.

To mirror the U-type layout (occupying bits [31:12] above rd), the offset bits are scrambled:

[31]    imm[20]    (1 bit)  - Sign bit stays at bit 31
[30:21] imm[10:1]  (10 bits)
[20]    imm[11]    (1 bit)
[19:12] imm[19:12] (8 bits)
[11:7]  rd         (5 bits) - Link register (ra = x1 for standard function calls)
[6:0]   opcode     (7 bits) = 1101111 (0x6F)

Worked Example: jal x1, 2048

Call a function at offset +2048 bytes, saving the return address into x1 (ra):

  • Offset: +2048 = 0b000000000100000000000 (21-bit binary with bit 11 = 1, all other bits 0).
  • imm[20] = 0
  • imm[19:12] = 00000000
  • imm[11] = 1
  • imm[10:1] = 0000000000
  • imm[0] = 0 (omitted)

Assemble the scrambled bits into instruction slot [31:12]:

  • Bit [31] (imm[20]): 0
  • Bits [30:21] (imm[10:1]): 0000000000
  • Bit [20] (imm[11]): 1
  • Bits [19:12] (imm[19:12]): 00000000
  • Upper 20 bits: 00000000000100000000
  • Bits [11:7] (rd): 00001 (x1)
  • Bits [6:0] (opcode): 1101111 (0x6F)
Field Bits Binary Value Description
imm[20|10:1|11|19:12] [31:12] 00000000000100000000 2048 Scrambled 21-bit jump offset
rd [11:7] 00001 1 (ra) Link register to receive PC + 4
opcode [6:0] 1101111 0x6F J-type unconditional jump opcode

Combining the fields:

Binary:  00000000000100000000 00001 1101111
Grouped: 0000 0000 0001 0000 0000 0000 1110 1111
Hex:     0x001000EF

Summary Reference Table

The table below provides a quick lookup for every format, showing the exact bit positions and textbook examples verified by the encoder:

Format Opcode Hex Key Identifying Fields Assembly Example Encoded Hex Word
R-Type 0x33 funct7=[31:25], rs2=[24:20], rs1=[19:15], funct3=[14:12], rd=[11:7] add x1, x2, x3 0x003100B3
I-Type 0x13, 0x03, 0x67 imm[11:0]=[31:20], rs1=[19:15], funct3=[14:12], rd=[11:7] addi x5, x4, 5 0x00520293
S-Type 0x23 imm[11:5]=[31:25], rs2=[24:20], rs1=[19:15], imm[4:0]=[11:7] sw x1, 12(x2) 0x00112623
B-Type 0x63 imm[12|10:5]=[31:25], rs2=[24:20], rs1=[19:15], imm[4:1|11]=[11:7] beq x1, x2, 16 0x00208863
U-Type 0x37, 0x17 imm[31:12]=[31:12], rd=[11:7] lui x5, 0x12345 0x123452B7
J-Type 0x6F imm[20|10:1|11|19:12]=[31:12], rd=[11:7] jal x1, 2048 0x001000EF

Five Common Exam Pitfalls

  1. Forgetting that branch and jump offsets omit bit 0: In B-type and J-type instructions, the immediate value is a byte offset, not an instruction count. Because instructions must be aligned, bit 0 is always 0 and omitted from the machine code. If a question asks for a branch to PC + 8, the encoded immediate is 8, but its bit 0 is dropped during placement.
  2. Mixing up rs1 and rs2 in store instructions: In sw rs2, offset(rs1), the register written to memory is rs2, while the base address register is rs1. Beginners frequently swap them because rs2 appears first in the assembly syntax.
  3. Overlooking negative immediate sign extension: addi, lw, and sw use 12-bit signed offsets. Values above 2047 wrap into negative numbers. For example, 0xFFF is -1, not 4095.
  4. Scrambling immediate bits incorrectly on paper: When assembling B-type instructions manually, remember that bit 11 goes into bit 7 of the machine word, while bits [4:1] go into bits [11:8].
  5. Confusing ABI names and numeric registers: Remember that zero is x0, ra is x1, sp is x2, t0–t2 are x5–x7, s0/fp is x8, and a0–a7 are x10–x17.

Verify Encodings Online

You can assemble any RV32I instruction or decode raw hex words step by step with the interactive RISC-V instruction encoder. It highlights every bit field, shows ABI and numeric register translations, and flags syntax errors instantly. For cache and memory layout topics, see the cache mapping guide.

Use the Binary Calculator to practice the accompanying binary arithmetic.

Looking for other tools?